4 fibers universal central loose tube cables, Euroclass Dca - s2, d1, a1, OS2 9/125 μm (ITU-T G.652.D)

Cable construction: Loose tube, Performance category: OS2 singlemode, Number of fibers: 4, Reaction to fire: Dca
P/N: CLTD04OS2-Dca
km
  • fully dielectric construction, halogen-free LSFROH sheath
  • tensile elements made of water blocking glass yarns
  • primary protection of 250 μm
  • central loose tube filled with water blocking gel
  • suitable for outdoor as well as for indoor environment
  • resistant to moisture, water and UV radiation
  • partial rodent protection (glass rodent protection - GRP)
  • ideal for horizontal campus duct installations using blowing and pulling technique

 

 

Technical specification

Standard temperature range (installation) -5 °C až +50 °C
Standard temperature range (operation) -30 °C až +70 °C
Min. bending radius (installation) 104 mm
Min. bending radius (operation) 52 mm
Max. tensile load (installation) 1000 N (100 kg)
Outer cable diameter 5,2 mm
Weight 33 kg / km
Number of tubes x number of fibers 1 x 4
Reaction to fire Dca - s2, d1, a1
Fire safety fire retardant, low smoke, zero halogen, non-corrosive

Certificates and Warranties

 


The determination of Reaction to Fire Class Performance of this cable has been performed by Product Certification Body notified by European Commision, which also carries out the assessment and verification of constant performance (AVCP) in the System 3.

 
 


25-Year System Warranty