Principles of optical cabling selection in terms of performance and transmission properties are described here. This applies to all components: cables, pigtails, adapters and patch cords.When choosing cables, it is necessary to consider the selection of their construction, which must comply with the operational and installation conditions.

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
4 fibers 
		
	
	universal distribution tight buffered cables, Euroclass Eca, OM1 62,5/125 μm
P/N: TB04OM1-Eca
  • fully dielectric and gel-free construction, halogen-free sheath    
  • tensile elements made of glass yarns
OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
4 fibers universal central loose tube cables, Euroclass Eca , OM1 62,5/125 μm
P/N: CLTD04OM1-Eca

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
180 min
180 min
Fire resistance cable with guaranteed functionality during a fire for the time indicated in the pictogram
LSFR0H
LSFR0H
low smoke and halogen-free and fire retardant cable, tested according to EN 60332-3-22 (Cat.), designed for areas with a higher concentration of people and areas with important electronic devices
4 fibers fire-resistant universal central loose tube cables, 180 min. at  750°C , OM1 62,5/125 μm
P/N: CLTFR04OM1

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
pancier
pancier
Armoured cable suitable for direct burial campus backbone applications, cable channels and cable bridges without the need for additional protection. Designed for heavy industrial environments where there is an increased risk of mechanical damage.
GRP 100%
GRP 100%

cable with 100% rodent protection

Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
4 fibres armoured central loose tube cable, Euroclass Eca , OM1 62,5/125 μm
P/N: CLTD04OM1-PANC-Eca
  • halogen-free sheath 
  • corrugated steel tape armor 
OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
8 fibers universal distribution tight buffered cables, Euroclass Eca , OM1 62,5/125 μm
P/N: TB08OM1-Eca
  • fully dielectric and gel-free construction, halogen-free sheath    
  • tensile elements made of glass yarns

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
8 fibers universal central loose tube cables, Euroclass Eca , OM1 62,5/125 μm
P/N: CLTD08OM1-Eca

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
180 min
180 min
Fire resistance cable with guaranteed functionality during a fire for the time indicated in the pictogram
LSFR0H
LSFR0H
low smoke and halogen-free and fire retardant cable, tested according to EN 60332-3-22 (Cat.), designed for areas with a higher concentration of people and areas with important electronic devices
8 fibers fire-resistant universal central loose tube cables, 180 min. at  750°C , OM1 62,5/125 μm
P/N: CLTFR08OM1

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
pancier
pancier
Armoured cable suitable for direct burial campus backbone applications, cable channels and cable bridges without the need for additional protection. Designed for heavy industrial environments where there is an increased risk of mechanical damage.
GRP 100%
GRP 100%

cable with 100% rodent protection

Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
8 fibres armoured central loose tube cable, Euroclass Eca , OM1 50/125 μm
P/N: CLTD08OM1-PANC-Eca
  • halogen-free sheath 
  • corrugated steel tape armor 
OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
12 fibers universal distribution tight buffered cables, Euroclass Eca , OM1 62,5/125 μm
P/N: TB12OM1-Eca

  • fully dielectric and gel-free construction, halogen-free sheath    
  • tensile elements made of glass yarns

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
12 fibers universal central loose tube cables, Euroclass Eca , OM1 62,5/125 μm
P/N: CLTD12OM1-Eca

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
GRP partial
GRP partial
cable with partial rodent protection (GRP - glass rodent protection)
180 min
180 min
Fire resistance cable with guaranteed functionality during a fire for the time indicated in the pictogram
LSFR0H
LSFR0H
low smoke and halogen-free and fire retardant cable, tested according to EN 60332-3-22 (Cat.), designed for areas with a higher concentration of people and areas with important electronic devices
12 fibers fire-resistant universal central loose tube cables, 180 min. at  750°C , OM1 62,5/125 μm
P/N: CLTFR12OM1

  • fully dielectric construction, halogen-free sheath
  • central loose tube filled with water blocking gel

OM1
OM1
meeting the requirements of performance category OM1 multimode
INDOOR / OUTDOOR
INDOOR / OUTDOOR
suitable for indoor environment, complies with all fire and safety regulations in buildings, due to its temperature range, resistance to moisture, water and UV radiation, this cable is suitable for outdoor use
pancier
pancier
Armoured cable suitable for direct burial campus backbone applications, cable channels and cable bridges without the need for additional protection. Designed for heavy industrial environments where there is an increased risk of mechanical damage.
GRP 100%
GRP 100%

cable with 100% rodent protection

Eca
Eca

Reaction to fire class according to EN 50575: 2014

LSOH
LSOH
low smoke, halogen-free cable resistant to flame propagation, designed for areas with higher concentration of people and areas with important electronic devices
12 fibres armoured central loose tube cable, Euroclass Eca , OM1 62,5/125 μm
P/N: CLTD12OM1-PANC-Eca
  • halogen-free sheath 
  • corrugated steel tape armor 
Results per page 12 24 48
Products
Component
Variant
Type
Height
Width
Depth
Capacity
Performance categories
Shielding
Patch cable length
Base dimensions
Color
Cable construction
Number of fibers
Number of ports
Splice protection length
Connector
Connectors
Sheath
Environment
Construction
Type
Number of ports
Over voltage protection
Inner height
Inner width
Width of frame bar
Cable length
Number of ventilators
Input (W)
Reaction to fire
2018 © All rights reserverd.